IS-B50HU-C1 Broadband DC Blocked Protector
|
|
IS-B50HU-C0 DC Blocked Protector
|
|
1" Flat Tinned Grounding Braid - 25 FT
|
|
IS-B50LU-C1 Broadband DC Blocked Protector
|
|
|
|
|
|
|
|
|
|
Single transmitter coaxial lightning protection for 50 MHz with UHF female connectors. Bulkhead mounted, broadband DC blocked protector.
Specifications:
Mount Type: Bulkhead Frequency Range: 50 MHz to 700 MHz Protected Side Conector: UHF Female Surge Side Connector: UHF Female Turn On Voltage: ±1200 Vdc ± 20 % VSWR: = 1.2:1 @ 50 MHz to 700 MHz Insertion Loss: = 0.1 dB RF Power: VHF 500 W, UHF 250 W
|
A single transmitter coaxial lightning protection for 1.5 MHz to 700 MHz with N female surge side connectors. Flange mounted, DC blocked protector.
Specifications:
Mount Type: Flange Frequency Range: 1.5 MHz to 700 MHz Protected Side Connector: UHF Female Turn On Voltage: ±1200 Vdc ± 20 % 7ns FOR 2kV /ns VSWR: =1.2:1 @ 1.5Mhz TO 700Mhz Insertion Loss: = 0.1dB RF Power: HF 3 kW, VHF 500 W, UHF 250 W
|
1" Flat Tinned Grounding Braid - 25 FT
|
A broadband dc blocked protector that is bulkhead mounted and offers single transmitter coaxial lightning protection for 50 MHz to 700 MHz with UHF female connectors.
Specifications:
Mount Type: Bulkhead Frequency Range: 50 MHz to 700 MHz Protected Side Connector: UHF Female Surge Side Connector: UHF Female Turn On Voltage: ± 600 Vdc ± 20% VSWR: = 1.2:1 @ 50 MHz to 700 MHz Insertion Loss: = 0.1 dB RF Power: VHF 375 W, UHF 125 W
|
|
|
IS-B50LU-C0 DC Blocked Protector
|
|
IS-50UX-C0 DC Blocked Protector
|
|
1" Flat Tinned Grounding Braid - 20 FT
|
|
IS-50UX-C1 DC Blocked Protector
|
|
|
|
|
|
|
|
|
|
The IS-B50LU-C0 is bulkhead mounted, DC block, single transmitter coaxial lightning protection for 1.5MHz to 400 MHz with UHF female surge side connectors.
Specifications:
Mount type: Bulkhead Frequency Range: 1.5 MHz to 400 MHz Protected Side Connector: UHF Male Surge Side Connector: UHF Female Turn On Voltage: 600 Vdc ± 20% VSWR: = 1.2:1 @ 1.5 MHz to 400 MHz Insertion Loss: = 0.1 dB RF Power: HF 2 kW, VHF 375 W, UHF 125 W
|
A DC blocked, flange mounted protector. Single transmitter coaxial lightning protection for 1.5 MHz to 700 MHz
with UHF female surge side and UHF female protected side connectors.
Specifications:
Mount Type: Flange Frequency Range: 1.5 MHz to 700 MHz Protected Side Connector: UHF Female Surge Side Connector: UHF Female Turn On Voltage: 600 Vdc ± 20% 2.5ns For 2kV VSWR: =1.2:1 @ 1.5Mhz To 700Mhz Insertion Loss: =0.1dB RF Power: HF 2 kW, VHF 375 W, UHF 125 W
|
1" Flat Tinned Grounding Braid - 20 FT
|
A flange mounted DC blocked connector. Single transmitter coaxial lightning protection for 50 MHz to 700 MHz with UHF female connectors.
Specifications:
Mount Type: Flange Frequency Range: 50 MHz to 700MHz Protected Side Connector: UHF Female Surge Side Connector: UHF Female Turn On Voltage: 600 Vdc ± 20 % VSWR: =1.2:1 50 to 700 MHz Insertion Loss: = 0.1 dB RF Power: VHF 375 W, UHF 125 W
|
|
|
IS-50NX-C0
|
|
Model ATT3G50U - Transi-Trap Surge Protection 200 Watts - UHF Connectors
|
|
Model ATT3G50UHP - Transi-Trap Surge Protection 2000 Watts - UHF Connectors
|
|
1" Flat Tinned Grounding Braid - 15 FT
|
|
|
|
|
|
|
|
|
|
|
1.5-400 MHz general coverage flange mounted protector. 50,000 amps surge. Power rating based on freq. N female on antenna port and N male on equipment port.
|
Lighting protection component from Alpha Delta. Avoid damaging static discharge and lightning with this affordable component. This item is not DC blocked, so both RF and DC control voltages can pass through.
|
Lighting protection component from Alpha Delta. Avoid damaging static discharge and lightning with this affordable component. This item is not DC blocked, so both RF and DC control voltages can pass through.
|
1" Flat Tinned Grounding Braid - 15 FT
|
|
|
Model ATT3G50HP - Transi-Trap Surge Protection 2000 Watts - N Connectors
|
|
No. 4 Earth Grounding Wire - 25 FT
|
|
No. 4 Earth Grounding Wire - 20 FT
|
|
1" Flat Tinned Grounding Braid - 10 FT
|
|
|
|
|
|
|
|
|
|
|
Lighting protection component from Alpha Delta. Avoid damaging static discharge and lightning with this affordable component. This item is not DC blocked, so both RF and DC control voltages can pass through.
|
No. 4 Earth Grounding Wire - 25 FT
|
No. 4 Earth Grounding Wire - 20 FT
|
1" Flat Tinned Grounding Braid - 10 FT
|
|